KINGSPAN K18 PDF

Kooltherm K18 Insulated Plasterboard is a super high performance insulated dry- lining plasterboard suitable for mechanical fixing. Buy mm Kingspan Kooltherm K18 Insulated Plasterboard, a premium performance fibre-free rigid thermoset phenolic insulation core bonded to mm. Kingspan Kooltherm K18 Insulated Plasterboard is a premium performance insulation, with a fibre-free rigid thermoset phenolic insulation core with mm .

Author: Maulkree Voodookasa
Country: Zimbabwe
Language: English (Spanish)
Genre: Art
Published (Last): 10 October 2012
Pages: 125
PDF File Size: 9.5 Mb
ePub File Size: 4.31 Mb
ISBN: 138-7-47339-170-5
Downloads: 21413
Price: Free* [*Free Regsitration Required]
Uploader: Groramar

A minimum of 20 mm bearing onto the timbers must be offered at each sheet joint. Care should be taken not to overdrive the fixing. The Old Stone House Aged not by years, but by its stories. Method of test to determine the classification of the surface spread of flame of products Result – Class 1 rating. If you do not click “Accept and close” but continue to use this website: We use cookies on our website www. Boards that have been allowed to get wet should not be used. The insulation core is resistant to short—term contact with petrol and with most dilute acids, alkalis and mineral oils.

Presently there are no availability restrictions, apart from manufacturing lead-times and minimum quantity order levels on the 70mm, 80mm, mm and mm boards.

Kingspan Insulation – Kooltherm K18 Insulated Plasterboard

Please click “Accept and close” to accept the use of cookies on our website. Water Vapour Resistance Modified to ,18 board facings, the boards achieve a resistance far greater than MN. You might also consider Celotex PL range which is a cheaper product with similar performance spec. The board should be fully restrained using mechanical fixings.

Method of test for fire propagation for products. Short lengths of metal framing should be fixed horizontally between the vertical pieces at skirting level, at the midpoint of the board and just below the ceiling or kingspwn level. Care should be kjngspan not to overdrive screws. Finishing Tapered edged boards allow the employment of standard dry—lining techniques. Resistance to Solvents The insulation core is resistant to short-term contact with petrol and with most dilute acids, alkalis and mineral oils.

  ANTIGENOS Y ANTICUERPOS ERITROCITARIOS PDF

The wall should be sound, dry and level as surface irregularities may impede fixing of the board.

Timbers should be treated where appropriate. Contact our experienced technical services department today. Fixings should be long enough to allow a minimum embedment of 20 mm into the mingspan. Finishing Tapered edged boards allow the employment of standard dry—lining techniques.

Timbers must offer a minimum 20 mm support to all four edges of the board.

Kingspan K18 Mechanically Fixed Insulated Plasterboard

Cutting Kingpsan should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side. Foil facings are conductive to electricity – avoid contact with un-insulated electrical cables and fittings. Installation is similar to that of standard plasterboard.

Installation is similar to that of standard plasterboard. We’re ready to help. Care should be taken not to overdrive the fixing. Fixing should kingsppan the same method as is used for the plain wall areas. Celotex FI range, for underfloor heating.

72.5mm Kingspan Kooltherm K18 Insulated Plasterboard – pack of 11

Test – BS —7: Method of test for fire propagation for products Result – Fire propagation index of Fire tests on building performance 1 not exceeding 12 and sub Index i1 not exceeding 6 kimgspan rigid phenolic insulation core Test – BS —7: Boards must always be placed with the long edge running across the joists, rafters or battens and all edges must be supported.

  INDIAN ALCHEMY OR RASAYANA PDF

Damaged boards or boards that have been in contact with harsh solvents or acids should not be used. Test – BS —7: Kingspan Kooltherm K18 Insulated Plasterboard may be used to line ceilings or infill where an exposed rafter is desired. Shopping Your basket is empty. Visit the store to add products to your basket.

We use cookies on our k8 www. Ensure fixings are located no less than 10 mm from the edges of the sheet. It should, therefore, not be used to isolate dampness nor be used in continuously damp or humid conditions. The timbers should run kinyspan and be wide enough to offer a minimum 20 mm support to all four edges of the board. Ensure that safe methods of cleaning are used, as recommended by the suppliers of the spilt liquid. National Archives Building, Christchurch A national treasure rises from the rubble.

The ceiling lining should be kingspaj position before wall lining commences. Damaged boards or boards that have been in contact with harsh solvents or acids should not be used. This method may be used on timber frame constructions or on any dry masonry walls that will support and retain the battens and associated fixings. Methods 7 to 9.

Fish River Ranger Accommodation Beating the heat. Specifications Thermal conductivity insulant thickness 0.

However, short lead times may apply.